8 best ways to connect cable cores and wires 1 prohibited


Existing methods of connecting conductors


Basic methods of connecting conductors in a house or apartment
Connecting wires can be done in several ways:

  • welding is the most reliable method, ensuring high reliability of the connection, but requiring skills and the presence of a welding machine;
  • terminal blocks - a simple and fairly reliable connection;
  • soldering - works well if the currents do not exceed the norm and the connection does not heat up to temperatures above the norm (65°C);
  • crimping with sleeves - requires knowledge of technology, special pliers, but the connection is reliable;
  • use of spring clamps - wago, PPE - are quickly installed and, subject to operating conditions, ensure good contact;
  • bolted connection - easy to perform, usually used in difficult cases - when it is necessary to switch from aluminum to copper and vice versa.

The specific type of connection is selected based on many factors. It is necessary to take into account the material of the conductor, its cross-section, the number of cores, the type of insulation, the number of conductors that will be connected, as well as operating conditions. Based on these factors, we will consider each type of connection.

What are distribution boxes for?

There are many factors that speak in favor of the existence of junction boxes:

  • The power system can be repaired in a matter of hours. All connections are accessible, you can easily find the area where the wires have burned out. If the cable was laid in special channels (corrugated tube, for example), then the failed cable can be replaced in an hour;
  • Connections can be inspected at any time. As a rule, wiring problems occur at the connection points. If the socket or switch does not work, but there is voltage in the network, first check the quality of the connection in the junction box;
  • the highest level of fire safety is created. It is believed that dangerous places are connections. Using a box will keep them in one place.
  • minimal time and financial costs when repairing wiring. There is no need to look for broken wires in the walls.

Welding – high reliability in any conditions

When connecting wires by welding, the conductors are twisted and their ends are welded. As a result, a metal ball is formed, which provides a stable and very reliable connection in any conditions. Moreover, it is reliable not only in terms of electrical characteristics, but also mechanically - the metal of the connected wires after melting forms a monolith and it is impossible to isolate a separate conductor.


Welding - it is important to heat the metal, but not melt the insulation

The disadvantage of this type of wire connection is that the connection is 100% permanent. If you need to change something, you need to cut off the fused piece and do it all over again. Therefore, for such connections, a certain supply of wires is left in case of possible alterations.

Other disadvantages include the need for a welding machine, appropriate electrodes, flux and operating skills. In addition, welding takes a lot of time, it is necessary to protect surrounding objects, and it is also inconvenient to work with a welder at height. Therefore, electricians practice this type of connection in exceptional cases. If you are doing it “for yourself” and know how to handle a welding machine well, you can practice on scraps. The main trick is to not melt the insulation, but to weld the metal.

After cooling, the welding site is isolated. You can use electrical tape, you can use heat shrink tubing.

Connecting sockets

Usually a separate line is allocated to the sockets. The box contains three cables of two or three conductors. Each wire is painted a different color. As a rule, brown is the phase, blue is the neutral conductor, and the yellow-green wire is ground. One way or another, in the box all the wires are connected by color, forming groups.

Once the conductors are separated by color, they are folded, stretched, and adjusted to the same length. Don't cut too short - leave a 100mm margin so that you can re-connect if necessary. Having chosen the appropriate connection method, you need to connect the wires.

In old houses there is no grounding, which means there will be only two wires. Sometimes the wires in the cable are the same color. To determine where the phase is and where the zero is, you need to use an indicator screwdriver to determine the phase.

Connecting wires by crimping

To crimp wires, a special aluminum or copper sleeve is required - it is selected based on the size of the twist (bundle diameter), and the material is the same as for the conductors. The bare wires, stripped to a shine, are twisted, a tube-sleeve is put on them, which is clamped with special pliers.


An example of crimping conductors with a sleeve

Both sleeves and pliers are different, there are several types. Each of them has its own rules of use (the number of wires that can be packed in a sleeve), which you need to be well versed in. It is necessary to pack the wires according to certain rules, measure the size of the resulting bundle, and adjust it to the requirements. In general, a rather dreary task. Therefore, this type of wire connection is mainly used by professional electricians, and more and more often they are switching to spring clamps.

Welding

In order for the connection of electrical wires to be as reliable as possible, the considered twisting method must be subsequently secured by welding. It is similar to soldering, only now a welding machine is used instead of a soldering iron.

Positive sides

This method is most preferable to all others, since it meets all regulatory requirements in terms of reliability and quality.

The welding method is based on contact heating of the ends of the wires with a carbon electrode until a ball (contact point) is formed. This ball is obtained as a single unit from the fused ends of all connected cores, which ensures safe and reliable contact; it will not weaken or oxidize over time.

Negative sides

The disadvantage of welding is that such work requires certain knowledge, experience, skills and special equipment; you often have to turn to specialists.

Installation

In order to connect wires using welding, you will need the following devices, tools and materials:

  • welding inverter with a power of at least 1 kW, its output voltage must be up to 24 V;
  • carbon or graphite electrode;
  • goggles or eye mask;
  • welding leather gloves to protect hands;
  • a mechanic's knife or stripper for removing the insulating layer from conductors;
  • sandpaper (for cleaning the conductive surfaces to be connected);
  • insulating tape for further insulation of the welding joint.

The sequence of work is as follows:

  1. Free each connected wire from 60-70 mm of insulation.
  2. Sand the exposed wires until they are shiny using sandpaper.
  3. Twist, after biting, the length of its ends should be at least 50 mm.
  4. Attach grounding clamps to the top of the twist.
  5. To ignite the arc, bring the electrode to the bottom of the twist and lightly touch the connected wires with it. Welding happens very quickly.
  6. It turns out to be a contact ball, give it time to cool, and then insulate it with tape.

As a result, an almost solid wire is obtained at the end, that is, the contact will have the lowest transition resistance.

If you connect copper wires in this way, then choose a carbon-copper electrode.

I would like to recommend that if you purchase a welding machine (it will be useful not only for connecting wires, but also for many other purposes), then choose the inverter option. With small dimensions, weight and electrical energy consumption, it has a wide range of welding current adjustment and produces a stable welding arc. And this is very important to be able to regulate the welding current. If you choose it correctly, the electrode will not stick and the arc will hold steady.

Watch how welding is done in this video:

We looked at the main types of wire connections. Now let’s briefly talk about methods that are used less frequently, but also guarantee quality and reliability.

Terminal blocks

One of the simplest and most reliable wire connections is through terminal blocks. There are several types, but almost all of them use a screw connection. There are sockets of different sizes - for different sizes of conductors, with different numbers of pairs - from 2 to 20 or more.

The terminal block itself is a plastic case in which a metal socket or plate is sealed. A bare conductor is inserted into this socket or between the plates and clamped with a screw. After the screw is tightened, you need to give the conductor a good tug to make sure it is tightly clamped. Due to the fact that the connection points remain uninsulated, the terminal blocks are used in rooms with normal humidity.

The disadvantage of such a connection: due to the ductility of metals - especially aluminum - the contact weakens over time, which can lead to an increase in the degree of heating and accelerated oxidation, which again leads to a decrease in contact. In general, the connection of wires in screw terminal boxes must be tightened periodically.


Connecting wires in terminal blocks

Advantages - speed, simplicity, low cost, does not require any skills, except the ability to use a screwdriver. Another important advantage is that you can easily connect wires of different diameters, single-core and stranded, copper and aluminum. There is no direct contact, so there are no risks.

Connectors for wires and cables

Connectors are special devices that facilitate the connection of two or more conductors. There are screw and clamping mechanisms.

Screw terminals

Used to connect wires of different materials and different diameters. An exception is multi-core electrical wires, which are crimped with special lugs. Also, screw clamps can damage aluminum wires, so it is better not to use them for such material.

Screw terminals


Allows you to connect aluminum and copper conductors together. They are easy to connect.

Power clamp

In such clamps, the stripped conductor is placed in the hole to the end. There it is automatically fixed by a pressure plate. Clamps can be used to secure copper and aluminum wires.

Clips

To install the wire, the clip clamp is placed in a vertical position, the wires are inserted inside, and then the clamp must be moved to a horizontal position. Plus, you can make adjustments.

Spring clamps


PPE caps are used as spring clips. Thanks to them, you can quickly make contact between two wires of similar diameters. It is important to choose the correct clamp, otherwise the contact will be unreliable.

Spring terminals

Wago spring terminals ensure reliable contact quickly and efficiently. However, over time, the spring may weaken or overheat.

Connection clamps

There are two types - electrical and electrical. The only difference is the current load. The connection takes place inside the device.

Couplings


It is made in the form of a metal tube. Used for conductors with a cross section of 0.25-16 mm. The wire is fixed by force crimping. Not used for single-core wires.

Soldering

First, about soldering technology. The connected conductors are stripped of insulation, cleared of the oxide film to bare metal, twisted, and then tinned. To do this, the conductors are heated with a soldering iron and applied to rosin. It should cover the joint completely. Tinned wires are twisted first with your fingers, then pressed using pliers. Instead of tinning, you can use soldering flux. They wet the wires well, but after twisting.

Then, in fact, the soldering process begins: the joint is heated with a soldering iron or narrow torch. When rosin or flux begins to boil, take some of the solder onto the soldering iron tip and bring it into the soldering zone, pressing the tip against the conductors. The solder flows to fill the gaps between the wires, making a good connection. When using a torch, solder is simply added little by little into the torch.

Next, after the soldering area has cooled, according to the technology, it is necessary to wash off the remaining flux (they accelerate oxidation), dry the joint, cover it with a special protective varnish, and then insulate it with electrical tape and/or heat-shrinkable tubes.

Now about the advantages and disadvantages of this method of connecting wires. In low-current systems, soldering is one of the most reliable methods of connecting wires. But, when installing electrical wiring in a house or apartment, it is criticized mercilessly. The thing is that solder has a low melting point. When large currents periodically pass through the connection (this happens if the circuit breakers are incorrectly selected or faulty), the solder gradually melts and evaporates. Over and over again, the contact becomes worse and the connection heats up more and more. If this process is not detected, the matter may well end in a fire.

The second negative point is the low mechanical strength of soldering. It's the tin again - it's soft. If there are a lot of wires in a soldered joint, and if they are also rigid, when you try to pack them, the conductors often fall out of the solder joint - the elastic force is too great, which pulls them out. That is why it is not recommended to use soldering connections when wiring electricity: it is inconvenient, time-consuming and risky.

Twist

Let's start with the simplest and most well-known method - twisting. It can also be called the oldest; it’s not for nothing that electricians call twisting the “old-fashioned method.”

We will not tell you that such a connection of wires is durable and reliable. According to the main document in electrical engineering, PUE (“Rules for Electrical Installations”), twisting is generally prohibited, despite the fact that half a century ago it was used everywhere. The fact is that in those days the load in the apartments consisted only of lighting, radio or television. If you consider the current load in modern apartments with a huge amount of household appliances used daily, then no old insulation, core cross-sections and methods of connecting wires are any longer suitable.

Nevertheless, we will talk about twisting, and even first of all, because it is the main stage of such connection options as welding and soldering.

Positive sides

The most important advantage of twisting is that it requires absolutely no material costs. All you need is a knife to remove the insulating layer from the wire cores and pliers to make the connection.

The second indisputable advantage of twisting is its ease of execution. You don’t need any special knowledge or skills; it can be done by anyone who has ever held pliers in their hands.

Several wires can be connected simultaneously in a twist, but their total number should not exceed six.

Negative sides

The main disadvantage of twisting is its unreliability; it weakens over time. This is due to the fact that there is residual elastic deformation in the cable or wire cores. At the point of twisting, the contact resistance increases, which can lead to contact failure and heating. In the best case, you will detect this in time and re-seal the connection; in the worst case, a fire may occur.

Electrical wires made of different metals cannot be connected using twisting. As an exception, you can twist copper and aluminum wire, but only if the copper core is first tinned with solder.

In electrical engineering there are concepts of detachable or permanent connection. So twisting does not apply to one or the other. A detachable connection is characterized by the fact that its ends can be disconnected many times. This cannot be fully done in twisting; every time after the next unwinding and twisting of the cores, they will deteriorate. It is also impossible to call twisting a permanent connection, because it does not contain the concepts of strength, reliability and stability necessary for this. This is another disadvantage of the twist connection.

Installation

If for some reason you do not have the opportunity to use other methods of connecting electrical wires, you can use twisting, just do it well. Very often it is used as a temporary option and is subsequently replaced by more reliable switching methods.

How to connect wires using twist? To begin with, the cores are stripped to 70-80 mm. The main thing is to twist all switched conductors into one single twist at the same time, and not wind one around the other.

Many people mistakenly begin to twist the wires together from the place where the insulating layer ends. But it is better in this place to clamp both wires with one pair of pliers, and with the other, grab the ends of the wires and perform rotational movements in a clockwise direction.

If the wire cross-section is small, you can twist it by hand. Align the conductors along the cut of the insulation and hold them firmly in this place with your left hand. Bend all switchable ends into one single bend at an angle of 90 degrees (a bend length of 10-15 mm will be enough). Hold this bend with your right hand and rotate clockwise. This must be done firmly and firmly. If it is already difficult to twist your hands at the end, use pliers as described above. As soon as the twist becomes smooth and beautiful, you can trim the bend.

You can connect several wires this way, but then to make it easier to twist them, make the bend longer, somewhere around 20-30 mm.

How to properly twist wires is shown in this video:

There is also a way to twist wires using a screwdriver, see about it here:

For information on twisting wires using a special tool, see here:

Now the resulting twist must be carefully insulated. Electrical tape is used for this. Do not spare it, wind it in several layers, and insulate not only the connection itself, but also step 2-3 cm over the core insulation. This way, you will ensure the insulating reliability of the twist and protect the contact connection from moisture.

You can also insulate the connection of wires using heat pipes. The main thing is not to forget to put the tube on one of the cores to be connected in advance, and then push it into the place where it is twisted. When exposed to heat, the thermal tube shrinks, so slightly heat its edges and it will firmly grip the wire, thereby providing reliable insulation.

If the twisting is done well, there is a chance that it will serve you for many years, provided that the load current in the network is normal. But it’s still better not to stop at this stage and strengthen the joint by welding or soldering.

Spring clamps for connecting wires

One of the most controversial ways to connect wires is using spring clamps. There are several types, but the two most common are wago terminal blocks and PPE caps. Externally and in terms of installation method, they are very different, but both designs are based on a spring, which creates strong contact with the wire.

There is controversy about this spring. Opponents of using wago say that the spring will weaken over time, the contact will become worse, the connection will begin to heat up more and more, which, again, leads to an even more rapid decrease in the degree of elasticity of the spring. After some time, the temperature may rise so much that the body (plastic) will melt, but what can happen next is known.


Spring clamps for electrical wiring - popular connections for wires

In defense of using spring clamps to connect wires, if they are used according to manufacturers' recommendations, problems are very, very rare. Although there are many fakes of both wago and PPE, as well as a sufficient number of photographs of them in melted form. But, at the same time, many people use them, and, under normal operating conditions, they work for years without complaints.

wago wire clamps

They appeared on our market several years ago and made a lot of noise: with their help, the connection is very quick and easy, and at the same time has high reliability. The manufacturer has specific recommendations for using this product:

  • wago should only be used for single-core or stranded conductors with a cross-section from 0.5 mm2 to 4 mm2;
  • to fix and connect stranded and small-diameter wires, use the CAGE CLAMP - from 0.08 mm2 to 35 mm2; What's inside wago wire clamps

Inside these devices there is a metal plate, which ensures the proper degree of contact. The shape and its parameters of the plates were specially developed and tested. The tests were carried out on a vibration stand for many hours, then heated and cooled. After which the electrical parameters of the connection were checked. All tests were passed “excellent” and branded products always perform “five”.

In general, the range of Wago products is very wide, but for installing electrical wiring or connecting home appliances and lighting fixtures, two types of wire clamps are used: series 222 (detachable) with the ability to reconnect or change the connection, and series 773 and 273 - which are called permanent.

Detachable

Spring clamps for electrical wiring Wago 222 series have a certain number of contact pads - from two to five - and the same number of locking flags. Before starting the connection, the flags are raised up, the conductors stripped of insulation are inserted into them (all the way), after which the flag is lowered. At this point the connection is considered complete.

Wago wire connectors - connection methods

If necessary, you can reconnect the connection - lift the locking flag and remove the conductor. Convenient, fast and reliable.


Wago 222 series range

The 222 Vago series can be used to connect two or three, even five conductors made of copper or aluminum (you can connect different metals in one terminal). Wires can be single-core or multi-core, but with rigid wires. The maximum cross-section is 2.5 mm2. Soft stranded wires can be connected with a cross-section from 0.08 mm2 to 4 mm2.

One-piece

There is another type of clamps that does not provide the ability to redo the connection of wires - series 773 and 273. When using these terminals, the work is generally done in seconds: the stripped wire is inserted into the appropriate socket. The spring present there clamps it, ensuring contact with the plate. All.


wago contact terminals

These spring loaded wire clamps can be used to connect solid aluminum or copper wires with cross-sectional area from 0.75 mm2 to 2.5 mm2, stranded wires with rigid wires from 1.5 mm2 to 2.5 mm2. Soft stranded conductors cannot be connected using such connectors.


Types of mounting terminals for wago wiring

To improve contact, the wires must be cleaned of oxide film before connecting. To prevent oxidation from continuing, wago manufacturers also produce contact paste. The inside of the clamp is filled with it and it itself corrodes the oxide film, and then protects the wires from oxidation in the future. In this case, only heavily oxidized, dark conductors need preliminary stripping, and the clamp body is filled with paste.

By the way, manufacturers say that, if desired, the wire can be pulled out of the clamp. To do this, grab the wire with one hand, hold the terminal box with the other and rotate them back and forth with a small range, in opposite directions, stretching them in different directions.

Clamps for lamps (construction and installation terminals for lamps)

For quick and convenient connection of lamps or sconces, wago has special 224 series terminals. With their help, you can connect aluminum or copper wires of different sections and types (single-core or stranded with rigid wires). The rated voltage of this connection is 400 V, rated current:

  • for copper conductors - 24 A
  • 16 A for aluminum.

Methods for connecting wires in chandeliers and sconces using wago clamps
Cross-section of connected conductors from the mounting side:

  • copper 1.0 ÷ 2.5 mm2 – single-core;
  • aluminum 2.5 mm2 – single-core.

Cross-section of connected conductors on the side of the chandelier/sconce: copper 0.5 ÷ 2.5 mm2 – single-core, stranded, tinned, crimped.

When connecting aluminum wires, it is necessary to use contact paste, and copper wires must be stripped by hand to bare metal.

This product has two disadvantages. The first is that the price of original terminals is high. Secondly, there are a lot of fakes at a lower price, but their quality is much lower and they burn and melt. Therefore, despite the high cost, it is better to buy original products.

PPE caps

PPE caps (which stands for “connector insulating clips”) are very easy to use devices. This is a plastic case, inside of which there is a spring that has a conical shape. The conductors, stripped of insulation, are inserted into the cap, and the cap is turned clockwise several times. You will feel that it has stopped scrolling, which means the connection is ready.


How to make a wire connection using PPE

These conductor connectors are produced by many manufacturers; they are available in different sizes, for different diameters and the number of connected conductors. In order for the wire connection to be reliable, the size must be selected correctly, and for this you need to understand the markings.

After the letters PPE there are several numbers. Depending on the manufacturer, the number of numbers varies, but they mean the same things. For example, there is this type of marking: SIZ-1 1.5-3.5 or SIZ-2 4.5-12. In this case, the number immediately following the letters indicates the type of case. “1” is set if the body is a regular cone, on the surface of which grooves can be applied for better grip. If there is a SIZ-2, then there are small protrusions on the body that are convenient to grasp with your fingers and twist.

All other numbers reflect the total cross-section of all conductors that can be connected using this particular PPE cap.


An example of marking of PPE caps and its explanation

For example, PPE-1 2.0-4.0. This means that the body of the connecting cap is ordinary, cone-shaped. With its help, you can connect two conductors with a cross section of at least 0.5 mm2 (in total they give 1 mm, which meets the minimum requirements - see the table). This cap contains a maximum of conductors whose total cross-section should not exceed 4 mm2.


Connecting wires using PPE caps

In the second version of marking, after the abbreviation PPE there is only a number from 1 to 5. In this case, you just need to remember which of them is useful for which cross-section of wires. The data is in another table.


PPE caps and their parameters

By the way, only copper wires can be connected with PPE caps - aluminum wires, as a rule, are thicker than the maximum allowable for these connectors.

Removing the insulating layer from the wires

I would like to immediately dwell on a question that will be common to any method. Before connecting the wires into a common electrical unit, they must be stripped of the top insulating layer.

This can be done using a mechanic's knife. This method is simple, but there is a high probability of damage to the conductor. To do everything correctly, you must strictly follow the step-by-step instructions:

  1. Place the wire on some flat surface (such as a table).
  2. Press it with your left index finger.
  3. With your right hand, take the knife and lightly press it into the insulating sheath of the wire. To avoid snagging the metal core, position it towards the cut at an angle. If the angle is right, there is a possibility of a circular cut in the core, as a result of which it may subsequently break.
  4. Hold the knife in this position. Using the index finger of your left hand, slowly twist the conductor one full turn, thus cutting the insulation around the entire circle.
  5. All that remains is to pull off the cut piece of insulation.

Professional electricians now necessarily have in their arsenal such a device as a stripper. This is a multifunctional tool that can be used to strip insulation from a wire or cut a cable. It can be simple, semi-automatic or automatic. The most important thing is that when stripping the insulation with a stripper, the conductor is not damaged. For each standard core diameter, such a tool has a calibrated hole with a cutting edge.

The length to which wire cores need to be stripped is different for each connection method.

Bolted connection

This connection is assembled from a bolt of any diameter, a suitable nut and one, or better yet, three washers. It is assembled quickly and easily, serves quite a long time and reliably.


Bolted wire connection

First, the conductors are stripped of insulation and, if necessary, the top oxidized layer is removed. Next, a loop is formed from the stripped part, the internal diameter of which is equal to the diameter of the bolt. To make it easier, you can wrap the wire around the bolt and tighten it (middle option in the right picture). Afterwards it all comes together in this order:

  • A washer is placed on the bolt.
  • One of the conductors.
  • Second puck.
  • Another conductor.
  • Third puck.
  • Screw.

The connection is tightened first with your hands, then with the help of keys (you can take pliers). That's all, the connection is ready. It is used mainly if it is necessary to make a connection between wires made of copper and aluminum; it can also be used when connecting conductors of different diameters.

Safety Tips and Rules

Only craftsmen with a qualification group are allowed to weld.
Persons who have skills in working with a soldering iron are also allowed to solder. Cables may only be connected in the manner permitted for them. Do not work with damaged wiring. All exposed parts must be insulated.

You can connect the cables in different ways. The choice of connection method is determined by the material, cross-section diameter and other parameters. For electrical equipment to operate correctly, the conductors need to be connected securely. In case of unreliable contact, there is a risk of fire.

How to connect aluminum and copper conductors

By the way, let us remind you why you cannot directly connect copper and aluminum wires. There are two reasons:

  • This connection gets very hot, which in itself is very bad.
  • Over time, the contact weakens. This happens because aluminum has a lower electrical conductivity than copper, and as a result, when the same currents pass through, it heats up more. When heated, it expands more, squeezing out the copper conductor - the connection becomes worse and gets hotter.

To avoid such troubles, copper and aluminum conductors are connected using:

  • terminal blocks;
  • wago;
  • bolted connection;
  • branch clamps (make connections of wires on the street).

Other types of connectors cannot be used.

Modern technologies

In many cases, the methods discussed are gradually becoming a thing of the past. They were replaced by factory wire connectors, which made installation and switching work much easier and faster:

  1. Terminal blocks, inside of which there are tubular brass sleeves. Stripped wire strands are inserted into these tubes and secured by tightening the screws.
  2. PPE caps, inside of which there are compression springs. The cores are inserted into the cap and then turned clockwise with little effort, thereby reliably compressing the connected wires inside.
  3. Self-clamping terminals. It is enough to place the wiring in them, and there it is automatically fixed due to the pressure plate.
  4. Lever-type terminal blocks. This connecting element is reusable. It is enough just to lift the lever, insert the conductor into the contact hole and lower the lever back, reliable fixation is ensured.

We do not talk in detail about all existing terminal blocks, since there is a separate article about this, where each type of wire clamp is discussed in detail.

We hope that we have clearly explained to you how to connect the wires correctly. Choose the method that suits you best. When choosing, take into account the cross-section and material of the conductors, the location of the connection (outdoors or indoors), and the amount of load current that will flow in this electrical circuit.

TV coaxial cable connection

It is possible to extend or splice a coaxial television cable in three ways: – TV extension, commercially available from 2 to 20 meters – using an adapter TV F socket - F socket; - soldering with a soldering iron.

You can familiarize yourself with step-by-step instructions for connecting a coaxial television cable by visiting a separate article on the site “Connecting a TV cable.”

Connecting tinsel wire by twisting with a single-core or stranded conductor

If it is necessary to give the cord very high flexibility and at the same time greater durability, the wires are made using a special technology. Its essence lies in winding very thin copper ribbons onto a cotton thread. This kind of wire is called tinsel.

The name is borrowed from tailors. Gold tinsel is used to embroider the ceremonial uniforms of high-ranking military officers, coats of arms and much more. Copper tinsel wires are currently used in the production of high-quality products - headphones, landline phones, that is, when the cord is subjected to intense bending during use of the product.

In a cord of tinsel conductors, as a rule, there are several and they are twisted together. It is almost impossible to solder such a conductor. To attach tinsel to the contacts of products, the ends of the conductors are crimped into the terminals with a special tool. To make a reliable and mechanically strong twist connection without tools, you can use the following technology.

The insulation is removed from the 10-15 mm tinsel conductors and the conductors with which it is necessary to connect the tinsel to a length of 20-25 mm with a shift using a knife in the manner described in the site article “Preparing wires for installation.” The tinsel thread is not removed.

Then the wires and the cord are applied to each other, the tinsel is bent along the conductor and the wire core is tightly wound onto the tinsel pressed against the insulation. It is enough to make three to five revolutions. Next, the second conductor is twisted. You will get a fairly strong twist with a shift. Several turns of insulating tape are wound and the twisted connection of the tinsel to a single-core wire is ready. Thanks to shear twisting technology, the connections do not need to be separately insulated. If you have a heat-shrinkable or polyvinyl chloride tube of a suitable diameter, you can put on a piece of it instead of insulating tape.

If you want to get a straight connection, you need to rotate the single-core wire 180° before insulating it. The mechanical strength of the twist will be greater. The connection of two cords with tinsel-type conductors to each other is carried out using the technology described above, only for wrapping, a piece of copper wire with a diameter of about 0.3-0.5 mm is taken and at least 8 turns must be made.

Wago


The next type is Wago terminal blocks. They also come in different sizes, and for different numbers of connected wires - two, three, five, eight.

They can connect both monocores and stranded wires together.

Moreover, this can be implemented both in different types of Vago, and in just one.

For stranded ones, the clamp must have a latch-flag, which, when open, easily allows you to insert the wire and clamp it inside after latching.

According to the manufacturer, these terminal blocks in home wiring can easily withstand loads of up to 24A (lights, sockets).

There are some compact specimens also available for 32A-41A.

Here are the most popular types of Wago clamps, their markings, characteristics and what cross-section they are designed for:

Series 2273 Series 221-222 Series 243 Series 773 Series 224

There is also an industrial series for cable cross-sections up to 95mm2. Their terminals are really large, but the principle of operation is almost the same as that of small ones.

When you measure the load on such terminals, with a current value of more than 200A, and at the same time you see that nothing is burning or heating, many doubts about Wago products disappear.

If you have original Vago clamps, and not a Chinese counterfeit, and the line is protected by a circuit breaker with a correctly selected setting, then this type of connection can rightfully be called the simplest, most modern and convenient to install.

Violate any of the above conditions and the result will be quite natural.

Therefore, there is no need to install wago at 24A and at the same time protect such wiring with a 25A automatic. In this case, the contact will burn out if overloaded.

Always choose the right terminal blocks for your car.

As a rule, you already have automatic machines, and they primarily protect the electrical wiring, and not the load and the end consumer.

ZVI


There is also a fairly old type of connection, such as terminal blocks. ZVI – insulated screw clamp.

In appearance, this is a very simple screw connection of wires to each other. Again, it comes in different sections and different shapes.

Here are their technical characteristics (current, cross-section, dimensions, screw torque):

However, ZVI has a number of significant disadvantages, due to which it cannot be called the most successful and reliable connection.

Basically, you can only connect two wires to each other in this way. Unless, of course, you specifically choose large pads and shove several wires there. What to do is not recommended.

This screw connection works well for monocores, but not for stranded flexible wires.

For flexible wires, you will have to press them with NShVI lugs and incur additional costs.

You can find videos online where, as an experiment, transition resistances on different types of connections are measured with a microohmmeter.

Surprisingly, the lowest value is obtained for screw terminals.

But we should not forget that this experiment refers to “fresh contacts.” Try making the same measurements after a year or two of intensive use. The results will be completely different.

Squeeze the nut, as an option, branch the wire

And so, if we talk about this option of connecting and branching wires and cables, it is considered optimal. I decided to put him first. The nut squeeze is a simple design, see photo:

It is small in size and has a simple operating principle. I don’t even see the point in making instructions about this. This is what it looks like in cross section:

To make a branch of copper or aluminum wires in this way, you only need to put all the wires in their places. Next, we clamp everything and tighten the body. This method can be called the simplest and most effective. Plus, the cost of squeezing a nut is quite low

Pay attention to the article: how to connect wires

This is interesting: Measuring insulation resistance with a megaohmmeter: technique

How to twist with soldering to create reliable electrical contact: 3 ways

When soldering, reliable electrical contact is created due to the penetration of molten solder into all voids. Between the turns of twist and the solder, a strong bond of mutual diffusion of both metals is created.

Soldering provides a guaranteed durable electrical contact with good conductivity. It requires adherence to certain technology and high-quality training.

It is necessary to remove the insulation from the wires, clean the metal cores from oxides, and impregnate it with flux. It will remove all organic contaminants from the prepared surface.

Acidic fluxes, such as a solution of zinc in sulfuric acid or aspirin, are difficult to remove from the surface of soldered parts. Over time, the remaining droplets enter into a chemical reaction with the metal of the veins and disrupt their conductivity.

Rosin is used for soldering electrical circuits. It can be dissolved in ethyl alcohol and applied with a brush to the wires to be connected.

When soldering twists, it is convenient to keep the prepared flux solution in a small bottle and simply dip the stripped and twisted wires into it one by one. This way you can work at heights.

Conventional electric soldering irons with resistive heating make this work difficult: you need to perform a lot of steps to distribute the solder over the surface of the twist and warm it up well.

For household electrical wires, it is convenient to use gas soldering irons, the flame of which is directed onto a special crucible with solder, mounted at a distance from the burner.

A twist treated with a rosin solution, even one located high above the ceiling in a distribution box, is placed for a short time in a crucible with molten solder and removed.

Similar work can be done with an electric soldering iron for polypropylene pipes. A certain part of electricians have adapted well and quickly to soldering strands with it.

Another modern way of obtaining high-quality soldering of almost any metal is to use solder paste, which is specially created for use in electrical installation work.

It is simply applied with a stick to the twist, as shown below for aluminum wire, and then heated in the flame of a burner.

The adhesion of metals is characterized by good current conductivity. For small amounts of electrical work in an apartment, you can get by with the flame of an ordinary lighter.

The paste has neutral acidity with a pH of about 7.5. It is used sparingly. If there is a lot of flux left at the soldering site, it can be easily washed off with water and wiped with a paper napkin.

ELP solder paste is recommended for connecting wires made of different metals, including copper and aluminum. It eliminates the effect of creating a galvanic couple due to the phenomenon of diffusion created by partial penetration of solder into the surface layer of the wires being soldered.

Which is the best way to connect wires?

As a rule, the wires are connected to each other in the following ways:

  • By welding. It is considered the most reliable method, but difficult to implement, since it requires a welding machine, as well as skills in handling it.
  • Using terminal clamps. Affordable and reliable connection.
  • Using soldering. The connection is reliable if the soldering points do not overheat.
  • Using crimping with sleeves. Although the connection is quite reliable, a special tool is required.
  • Using special spring clamps. Under certain conditions, it provides good contact, especially since the installation of such clamps does not require a long time.
  • With bolts. This type of connection is used in difficult situations when, for example, it is necessary to connect a copper conductor to an aluminum conductor.

Which method is appropriate for a particular case is determined by the availability of certain information. It is necessary to familiarize yourself with the wiring design, with their cross-section, with possible loads, with the type of insulation, with the nature of the conductors (single-core or stranded), etc. You will also have to take into account the operating conditions.

General recommendations for extending wires

Below are general recommendations for adding wiring yourself. They will help simplify electrical installation work and avoid problems in the future:

  1. The extension wire must be suitable for the permissible power. Ideally, the cable cross-section is selected with a margin.
  2. The insulation must not be damaged or cracked.
  3. If space allows, it is advisable to leave some reserve. A cable that is too long is more convenient than a short one.
  4. Wiring should not rest on sharp corners. She can get over them.
  5. Avoid exposed live parts and contact with construction mixtures.
  6. The PUE prohibits the use of twists, so it is advisable not to perform them.
  7. All work is carried out with an insulated tool and stress relief.

Any twist or branch is a minus one point to the reliability of the wiring. You can lengthen the electrical cable when there are compelling reasons for this. In most cases, it is preferable to replace the entire wire without unnecessary cuts.

If build-up is inevitable, then the twist must satisfy two criteria. Firstly, the contact is strong and reliable, especially in power circuits. Secondly, the junction is isolated. The absence of a protective layer can cause a fire or electrical injury.

Rating
( 2 ratings, average 5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]